Wood VDN logo

Vibration, dynamics and noise

formerly BETA Machinery and SVT

Menu

Services

Multiphase and Slug Flow Analysis

Impact on fatigue and dynamic stress in piping systems

Stress concentration around a pipe support due to unsteady multiphase flow
Stress concentration around a pipe support due to unsteady multiphase flow

Multiphase flow occurs when different fluid phases are mixed and flow in the same pipe. Depending on the phase velocities and densities and the ratio of liquid to gas, different flow regimes might exist - for example, stratified, slug or annular flow. Although slug flow is often considered to be the most problematic from a vibration perspective, recent experience has shown that other flow regimes can give rise to significant piping vibration.

In the oil and gas industry, multiphase flow is often encountered, and if not taken into account during the design of a process system, it can lead to excessive vibration, resulting in unreliable operation and eventually fatigue failure. 

Speak to a specialist

1 Why is multiphase flow an issue?

The risks from flow- or process-induced vibration excitation of pipework are widely acknowledged in onshore process plants, offshore topsides and subsea facilities. Multiphase flow is particularly of concern because forces can vary considerably with flow regimes, and so relatively small changes in the gas-to-oil ratio can result in significant changes in dynamic force levels. These forces can be relatively broadband in nature and can therefore excite a range of structural modes.

A stress or fatigue study should be considered when:

  • Flow rates are increased or changes to the gas-to-oil ratio are considered
  • Thermophysical properties of transported fluids are changed
  • Hydrodynamic- or terrain-induced slugging is possible
2 Design

A multiphase flow study starts with a detailed CFD analysis to predict the time-varying velocities, forces and pressure levels in the piping system. These forces are then applied on a structural model of the piping system to predict vibration and dynamic stress levels, which can then be compared with acceptance criteria to assess the severity of the flow conditions and predict the fatigue life of the system.

During the project design stage, we can support the project team through carrying out a range of high-end engineering services:

  • Force predictions to identify the amplitude and frequency content of the flow-induced forces
  • Mechanical natural frequencies (MNF) calculations to assess the risk of vibration modes being resonant
  • Guidance on optimal support locations to minimize thermal stresses and avoid resonance
  • Detailed simulation to identify the maximum vibration levels and dynamic stress amplitudes and how these vary with operating conditions

There are alternatives to CFD for certain types of multiphase flow:

  • For turbulent fluid flow, created by flow around discontinuities like elbows, tees, expanders, and partially opened valves, the force power spectral density (PSD) can be taken from industry research (from authors like Belfroid, Norton & Bull, and Kataoka). 
  • For simple slug flow, empirical calculations can be used to estimate the slug force on elbows.
3 Case study

An operator recently contacted Wood to investigate whether they could increase the flow rate in an existing 4” (100 mm) pipe connecting a Christmas tree to a production header.

Liquid velocity at the midplane of an elbow

Figure 1: Liquid velocity at the midplane of an elbow

The pipe was only supported at two locations, and important thermal distortions were predicted to change the support conditions during operation. The operator was worried that the new flow conditions would result in slug flow.

First, Wood modelled the flow in the pipe and predicted the velocity distribution. This is illustrated in Figure 1, which shows a typical liquid-velocity variation at the midplane of an elbow. High-velocity bands are observed as the flow travels around the elbow. The CFD model was then used to also predict pressure levels and calculate the time variation of forces generated in each direction and at different elbows (Figure 2).

The results showed a rapid variation of forces, along with fairly different force levels at each elbow due to the multiphase flow characteristics being modified as the flow progressed from bend to bend.

These forces were then applied to an FEA structural model to predict the transient response of the pipe. The Fast-Fourier Transform (FFT) of the vibration signals at key elbow locations were calculated and compared to the EI guideline vibration velocity limits (Figure 3). The results predicted the dominant response to be at 15, 40 and 85 Hz.

Figure 2: Time history corresponding to the horizontal force at one of the elbows
​
Vibration levels at elbow location compared to the Energy Institute (EI) Guideline
Figure 3: Vibration levels at elbow location compared to the Energy Institute (EI) Guideline
 
Stress Levels Around a Shoe Support
Figure 4: Stress levels around a shoe support
4 Research and joint industry projects (JIPs)
SLARP JIP slug loading testing setup
SLARP JIP slug loading FEA modelling
SLARP JIP testing setup and FEA model

Wood is managing a SLARP JIP, which deals with the development of methods for the design and analysis of slug loading and response in subsea pipelines, risers, jumpers and free-spans.

The JIP is structured around three key aspects:

  1. Development of global numerical analysis models for the prediction of pipeline and riser structural dynamic response to slug flow
  2. Full-scale model testing and global finite element analysis correlation
  3. Development of an industry design guideline reflecting best practice design and analysis techniques for determining structural response to slug flow

Phase 3 was formally kicked off in November 2014 and finished in January 2017. It expanded the testing and numerical validation that was completed as part of Phase 2 and provided enhanced knowledge, understanding and value to the development of the JIP design guidelines and analytical methods. Participants for Phase 3 included BP, Chevron, Total and Saipem.

5 Equivalent static load (ESL) analyses
Equivalent static load (ESL) modeled in piping system

Piping systems can experience transient type events like slugging flow and pressure pulsations created by rapid changes in the piping system (eg, water hammer events). Other transient events include pressure safety valve (PSV) opening events. 

Evaluating these specific types of events can be challenging because they require a full transient finite element analysis (FEA). Luckily, transient events can be effectively simulated by using an equivalent static load, rather than the full transient (time-varying) load. This methodology is called an Equivalent Static Load (ESL) analysis. This procedure is commonly used in other disciplines for evaluating impact loads or blasting loads.

A screening method for doing ESL analysis on piping systems subject to forces like slugging or water hammer is discussed in the ASME PVP paper PVP2026-179841.

Wood has created a technical primer on slug flow dynamic analysis using the ESL methodology.

6 Inquiries

Wood’s vibration, dynamics and noise (VDN) group has been involved in joint-industry projects (JIPs) for several years to understand and determine multiphase flow characteristics and the associated dynamic response of piping systems. Our team of experts provides a comprehensive analysis strategy for such flow conditions. The strategy is based on sophisticated simulation tools backed by experimental data.

For more details, or to discuss your specific multiphase flow concerns, please email our dedicated CFD and FEA experts at info.vdn@woodgroup.com.

Related services
Keywords
  • Multiphase flow
  • Slug flow
  • CFD
  • FEA
  • PSD
7 CFD examples

Back to top


Free webinar

Webinar

Learn how to reduce industrial noise and ensure compliance without disrupting operations.
Register now


BETA Machinery Analysis logo
SVT Engineering Consultants logo
Contact Us Privacy ©2026 Wood